Problem:
A
new addition was planned for an existing residence
in Newton, Massachusetts. A soil investigation
showed a deep layer of unsuitable soils within
the planned addition, requiring the use of a deep
foundation system. Pile driving was not feasible
due to the close proximity to nearby structures.
Solutions:
Helical anchors were chosen to support the new
foundation, as noise, vibrations, and a rapid
mobilization were considerations for the project.
Helical anchors are essentially vibration free
and do not require seismic monitoring of nearby
structures. Twenty one helical piles were successfully
installed for the job.